C – 00 Standard Test Methods for Chemical Analysis of Hydraulic Cement, chemical analysis, compositional analysis, hydraulic cements. ASTM Standards: 2. C 25 Test Methods for Chemical Analysis of Limestone,. Quicklime, and Hydrated Lime. D Specification for Reagent Water. ASTM C accreditation for cement analysis . are within the prescribed limits for iron, so acceptable (according to ASTM-C requirement).

Author: Golabar Yozshum
Country: Malta
Language: English (Spanish)
Genre: Science
Published (Last): 9 February 2008
Pages: 290
PDF File Size: 2.93 Mb
ePub File Size: 12.95 Mb
ISBN: 219-6-22596-489-9
Downloads: 53337
Price: Free* [*Free Regsitration Required]
Uploader: Faeramar

NOTE 1—A blank determination is a procedure which follows all steps of analysis but in the absence of a sample. Prepare three standards, each in duplicate: A cement shall not be rejected for failure to conform to chemical requirements unless all determinations of constituents involved and all necessary separations prior to the determination of any one constituent are made entirely by these methods.

A When seven CRM cements are required, as for demonstrating the performance of rapid test methods, at least six of the seven shall be within the prescribed limits and the seventh shall differ by no more qstm twice that value.

Referenced Documents purchase separately The documents asmt below are referenced within the subject standard but are not provided as part of the standard. Link to Active This link will always route to the current Active version of the standard. Any test methods of demonstrated acceptable precision and bias may be used for analysis of hydraulic cements, including analyses for referee and certification purposes, as explained in Section 4. No certificate value given. Requirements for Qualification Testing.

This abstract is a brief summary of the referenced standard. Historical Version s – view previous versions of standard Translated Version s: The reference test methods are long accepted classical chemical test methods which provide a reasonably asttm basic scheme of analysis for hydraulic cements.

When reporting the results of referee analyses, specify which test methods were used. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. It is the responsibility of the user astn this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Specific chemical test methods are provided for ease of reference for those desiring to use them. Recommended Order for Reporting Analyses. When a blank determination See Note 1 v114 s specified, one shall be made with each individual analysis or with each group of two or more samples analyzed on the same day for a given analyte.

  BARTLEBY Y COMPANIA PDF

No other units of measurement are included in this standard.

ASTM C – 09 Standard Test Methods for Chemical Analysis of Hydraulic Cement

Parte 1 de Link to Active This link will always route to the current Active version of the standard. Traceability consists of documentary evidence that the assigned values of the reference. Sodium and Potassium Oxides. NOTE 3—It is not intended that the use of reference test methods be confined to referee analysis. Reference test methods and procedures include determination of insoluble residue, silicon dioxide, ammonium hydroxide group, ferric f114, phosphorus pentoxide, titanium dioxide, zinc oxide, aluminum oxide, calcium oxide, magnesium oxide, sulfur, loss on ignition, sodium and potassium oxides, manganic oxide, chloride, chloroform-soluble organic substances.

CO 2 Determinations in Hydraulic Cements. A superscript epsilon indicates an editorial change since the last revision or reapproval. Satm of the analyst is required every two years. The alternative test methods generally provide individual determination of specific components and may be used alone or as alternates and determinations within the basic scheme at the option of the analyst and as indicated in the individual method.

This standard is issued under the fixed designation C; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. Performance Requirements for Rapid Test Methods.

Active view current version of standard. The same test methods to be used for analysis of cement being tested shall astmm used for analysis of the CRM cement. Standard reagents for the test method shall be used within the limits of the specification. Specific chemical test methods are provided for ease of reference for those desiring to use them.

ASTM C114 – 15 – Chemical Analysis of Hydraulic Cement

Apparatus and materials for the test method include balance, weights, glassware and laboratory containers, desiccators, filter paper, crucibles, and muffle furnace. No result shall deviate from the assigned value by more than the limits given in column 2 of Table 1.

The reference test methods are long accepted classical chemical test methods which provide a reasonably well-integrated basic scheme of analysis for hydraulic cements.

  MADELEINE VIONNET BETTY KIRKE PDF

Specific chemical test methods are provided for ease of reference for those desiring to use them. Any test methods of demonstrated acceptable precision and bias may be used for analysis of hydraulic cements, including analyses for referee and certification purposes, as explained in Section 3.

If either of the two requirements listed above are not met, identify and correct any problems or errors found in the procedure. When two or three results do agree within the permissible variation, their average shall be accepted as the correct value. Test results from alternative test methods may be used as a basis for acceptance or rejection when it is clear that a cement does or does not meet the specification requirement. Weigh and prepare two separate specimens of each standard.

Sodium and Potassium Oxides. No further reproductions authorized. CO2 from the certificate value by the mass fraction of Certified CaCO3 added to that standard percentage added divided by ; multiply the value determined for. Description of Referee Analyses. The reference test methods are long accepted classical chemical test methods which provide a reasonably well-integrated basic scheme of analysis for hydraulic cements.

The individual analyst must demonstrate achievement of acceptable precision and bias, as explained in Section 3, when these test methods are used. Any test methods of demonstrated acceptable precision and bias may be used for analysis of hydraulic cements, including analyses for referee and certification purposes, as explained in Section 4. Active view current version of standard.

When an average of either two or three results can be calculated, the calculation shall be based on the three results. The analyst is considered qualified when the difference between the duplicate results does not vary by more than the value listed in Column 2 of Table 1 and the average of the two samples agrees with the certificate value of the CRM within the limits listed in Column 3 of Table 1 after correction for minor components when needed.